Smart Gas Detector with LED Display – GT-2500-FLP

The GT-2500-FLP, a PESO certified Flameproof Smart Gas Detector/Transmitter, stands as a robust solution for the swift and dependable detection of Oxygen, Toxic, Combustible, and Volatile Organic Compounds (VOC) gas leaks. Its user-friendly design includes a 7-Segment LED display for digital gas concentration readouts and 8 LEDs providing clear indications of the instrument’s status. With a standard 4-20mA signal output and three relay outputs, each with a 5A rating for both AC and DC, it ensures seamless integration into monitoring systems. The optional Isolated RS-485 Communication Port with MODBUS RTU PROTOCOL enhances connectivity. The device boasts a hot-swappable gas sensor module, allowing for easy maintenance and servicing, and features non-intrusive programming for the Flameproof Model using a Magnetic Wand. Recognizing its versatility, it can detect gas concentrations down to PPM, %V/V, %LEL, and mg/m³, with indications for various conditions such as ‘Sensor Open,’ ‘Over Range,’ ‘Sensor Replace,’ ‘Cal Due,’ ‘Cal Fail,’ and ‘mA Loop Open.’ This comprehensive set of features positions the GT-2500-FLP as a reliable and efficient gas detection solution for diverse industrial applications.

1. Versatile Gas Detection: Gas Detector Detects the smallest leaks of Oxygen, Toxic, Combustible, and Volatile Organic Compounds (VOC).
2. Modular Design: Smart, pluggable gas sensor module for easy replacement and maintenance.
3. Data Storage: Calibration, alarm, offset, and output current data saved in the sensor module for efficient maintenance.
4. Poisoning Resistance: Gas Detector is Highly resistant to poisoning and etching for prolonged sensor life.
5. Detection Range: Capable of detecting down to PPM, %V/V, %LEL, mg/m3.
6. Display and Indicators: 2-Line, 4-Digit LED display with 8 LEDs indicating instrument status.
7. Alarm Indications: Alerts for ‘Sensor Open’, ‘Over Range’, ‘Sensor Replace’, ‘Cal Due’, ‘Cal Fail’, mA Loop Open.
8. Output Signals: Standard 4-20mA signal output with configurable range.
9. Optional Set Points: Configurable STEL and TWA set points for Toxic & VOC Gases.
10. Communication Options: Optional RS-485 Communication Port with MODBUS RTU PROTOCOL.
11. Non-Intrusive Programming: Flameproof model programmable using a magnetic wand without opening the enclosure cover.
12. Security Features: Password-protected programming with password changing facility.
13. Alarm Acknowledgement: Facility for acknowledging alarms from the front as well as the rear terminal.
14. Test Mode: Allows checking electronics, alarm LEDs, relays, and output current/voltage with or without a sensor module.
15. Relay Contacts: Optional relay contacts on board with two configurable alarm levels and one fail-safe relay.

Technical Specifications:

1. Flameproof Approval: Ex db IIC T6 Gb IP 66/IP68.
2. Certifications: CIMFR and PESO certificates for flameproof enclosure.
3. Intrinsically Safe Approval: Ex d [ia] IIC T6 Ga Ex tb IIIC T85°C Db IP68.
4. Sensor Technology: Electrochemical/Catalytic/Pellistor/NDIR/PID/Solid State.
5. Detection Method: Diffusion.
6. Response Time: Less than 15 seconds (Depending on the type of gas).
7. Power Supply: 18 to 36 VDC, Typically 24VDC.
8. Power Consumption: Less than 3.6 Watts.
9. Operating Temperature: -15 to +55°C.
10. Storage Temperature: -10 to 60°C.
11. Humidity: Less than 95% Non-Condensing.
12. Dimensions (Without Hooter cum Flasher): 225 mm (H) x 225 mm (W) x 122 mm (D).
13. Weight (Without Hooter cum Flasher): Approx. 2.2 kg.
14. Optional Accessories: Power supply, canopy & mounting stand, gas calibration kit, hooter cum flasher, gas sampling system, communication converters.
15. Common Deliverables:
Test calibration certificate, reference calibration gas certificate, operational/instrument user manual, standard mounting hardware.

Refineries Gas Cylinder Bank
Cold Storage Oil & Gas Industries
Sewage Plants Gas Pipeline Project
Fertilizers Plants Pulp & Paper Plants
Stack Monitoring Gas Metering Station
Chlorination Plant Burner / Furnace Areas
Ambient Monitoring Bullet Yard / Storage Yard
Gas Metering Skid Chemical Processing Plant
Gas Cylinder Bank Heat Treatment Plants
Oil & Gas Industries Chemical Storage Area
Gas Pipeline Project Control Atmosphere
Pulp & Paper Plants Power & Industrial Plants
Gas Metering Station Acid Alkalizes & Dyes Mfg. Plants
Burner / Furnace Areas Offshore Drilling & Processing Platforms
Bullet Yard / Storage Yard Coal Mine and Confined Area
Chemical Processing Plant Chemical & Petrochemical Plants
Heat Treatment Plants Automotive Industries / Paint Shops

Get Quote From Our Sales Team