Ambetronics

Home

Our Standard Certifications

Discover Our Specialized Application Solutions.

Pharma Plants
Hotel and Kitchen
Data Centers
HVAC
Water Treatment
Chlorination
Laboratory
Food Process Cold Chain Monitoring
Pharma Cold Chain Monitoring
Car Parking System
Hospital and Laboratory
City Gas Distribution
Steel Industry
Fertilizers

Dual Channel Smart Gas Detector | GT-5022-FLP

The GT-5022-FLP is a Dual Channel Smart Gas Detector designed for accurate and reliable detection of Oxygen, Toxic, Combustible Gases, and Volatile Organic Compounds (VOC). It features dual gas concentration indication, accommodating two gas sensor modules for versatile gas detection. The device offers fast response times and is capable of detecting gases down to PPM, %V/V, %LEL.Equipped with a digital LCD display, the detector provides real-time gas concentration readings. Calibration, alarm, offset, and output current data are stored in smart, pluggable gas sensor modules for easy maintenance. The device is highly resistant to poisoning and etching, ensuring robust performance.Key features include two independent alarm set points, configurable STEL and TWA set points for Toxic and VOC gases, and optional RS-485 communication with MODBUS RTU protocol. The Flameproof model adheres to safety standards with certifications such as Ex db IIC T6, making it suitable for various applications like refineries, cold storage, sewage plants, chemical processing plants, and more.

1. Dual Gas Concentration Indication:

– Dual Channel Smart Gas Detector simultaneous display of two gas concentrations for comprehensive monitoring.

2. Smart Gas Sensor Module Compatibility:

– Dual Channel Smart Gas Detector supports pluggable gas sensor modules for Oxygen, Toxic, Combustible, PID, and NDIR sensors.

3. Reliable Detection:

– Fast and reliable detection of smallest leaks of Oxygen, Toxic, Combustible Gases, and Volatile Organic Compounds (VOC).

4. Calibration and Maintenance:

– Calibration data, alarm data, offset data, and output current data stored in sensor module for easy maintenance.

5. Versatile Gas Detection:

– Capable of detecting down to PPM, %V/V, %LEL for diverse industrial applications.

6. Digital Display:

– Clear digital display of gas concentration on LCD for real-time monitoring.

7. Alarm Indications:

– Indications for ‘Sensor Open,’ ‘Over Range,’ ‘Sensor Replace,’ ‘Cal Due,’ ‘Cal Fail,’ ‘mA Loop Open’ for quick diagnostics.

8. Output Signal Options:

– Standard 4-20mA signal output with configurable range.
– Standard 0-10V/0-5V/0-1V signal output with configurable range.

9. Optional Set Points:

– Optional STEL and TWA set points can be configured for Toxic & VOC gases.

10. RS-485 Communication:

– Optional RS-485 Communication Port with MODBUS RTU Protocol for enhanced connectivity.

11. Non-Intrusive Programming:

– Non-intrusive programming for Flameproof Model using front keys.

12. Password Protection:

– Password-protected programming with password-changing facility for added security.

13. Alarm Acknowledgement:

– Alarm acknowledgement facility from front as well as rear terminal.

14. Test Mode:

– ‘Test Mode’ provided to check electronics, including Alarm LEDs, Relays, Output Current/Voltage with or without sensor module.

15. Optional Alarm Relay:

– Optional Alarm Relay contacts on board with two configurable Alarm Levels & One Fail-Safe Relay.

16. Approved and Compliant:

– Flameproof enclosure approved by PESO with Ex db IIC T6 (-20° ≤ Ta ≤ +60°C) Gb, T5 (-20° ≤ Ta ≤ +70°C) ratings.

17. Technical Specifications:

– Sensor Technology: Electrochemical/Catalytic/Pellistor/NDIR/PID
– Detection Method: Diffusion
– Gas Detected: (Specify gas as per table)
– Range & Resolution: (Specify Range & Resolution as per table)
– Display: Graphic LCD with settable backlight, 8 LEDs for instrument status.
– Control Action: Two independent Alarm set points with Latch & Non-latch facility.

18. Environmental Conditions:

– Operating Temperature: -15 to +50°C
– Storage Temperature: -10 to 60°C
– Humidity: Less than 95% Non-Condensing.

19. Electrical Specifications:

– Supply Voltage: 18 to 36 VDC, Typically 24VDC
– Power Consumption: Less than 3.6 Watts

20. Accessories (Optional):

– Certified 24 VDC Power Supply, Canopy & Mounting Stand, Gas Calibration Kit, Hooter Cum Flasher, Gas Sampling & Conditioning System, RS-485 to USB or RS-232 Converter, Ethernet Converter, PC-Based SCADA Software, Modem.

21. Flameproof Housing:

– Protection Class: IP-68
– Cabinet Material: Cast Aluminium alloy, LM-6

22. Common Deliverables:

– Test Calibration Certificate, Reference Calibration Gas Certificate, ‘Operational/Instrument’ User Manual, Standard Mounting Hardware.

23. Certifications:

– CIMFR Certificate No.: IN/CIMFR/TR23/P/136, Date: 19/04/2023
– PESO Certificate No.: P566724/1, Date: 13/07/2023

  • Gas Metering Skid Gas Cylinder Bank
    Sewage Plants Fertilizers Plants
    Chlorination Plant Oil & Gas Industries
    Gas Pipeline Project Pulp & Paper Plants
    Gas Metering Station Bullet Yards / Storage Yard
    Coal Mine and Confined Area Automotive Industrial/Paints Shops
    Burner / Furnace Areas Refineries
    Cold Storage Stack Monitoring
    Ambient Monitoring Chemical Processing Plant
    Acid Alkalis & Dyes Manufacturing Plants Offshore Drilling & Processing Platform
    Heat Treatment Plants Chemical Storage Area
    Control Atmosphere Power & Industrial Plants
    Chemical & Petrochemical Plants

Get Quote From Our Sales Team