Our Standard Certifications
16 Channel Data Logger | UIP-1600-PMH
The UIP-1600-PMH is a 16 Channel Data Logger designed for precise data monitoring in various applications. Featuring advanced microcontroller technology, this device offers 16 universal input channels supporting thermocouples (types J, K, R, S, T, B, N), RTD (PT-100), and 4-20mA programmable by the user. With a field-calibratable front panel membrane keypad, users can easily configure channel scan times (1-240 sec), logging intervals (1-9999 sec), and printing intervals (1-9999 sec).This versatile scanner is suitable for applications such as warehouse monitoring, ISO certification records, oven profiling, blood bank monitoring, and more. It ensures accuracy with error condition monitoring, displaying ‘Break/Open’ or ‘Under/Over Range’ indications. The UIP-1600-PMH provides two independent user-settable set points for each channel, with relay outputs (NO/C/NC) for alarms, and remote acknowledgment capabilities.
1. Advanced Technology: 16 Channel Data Logger utilizes the latest microcontroller-based technology for enhanced accuracy in data monitoring.
2. Universal Input Channels: Offers 16 channels supporting a variety of thermocouple types (J, K, R, S, T, B, N), RTD (PT-100), and 4-20mA, providing flexibility for different applications.
3. User-Friendly Calibration: Facilitates easy on-site calibration through a front panel membrane keypad, ensuring convenience and accuracy.
4. Customizable Scan Time: Field programmable channel scan time ranging from 1 to 240 seconds, allowing users to tailor the scanning process to specific requirements.
5. Adjustable Logging Intervals: Logging intervals can be programmed by the user, ranging from 1 to 9999 seconds, facilitating precise data recording.
6. Remote Acknowledgment: Includes a remote acknowledgment feature for relays, enhancing control and monitoring capabilities.
7. Optional Communication Ports: Provides optional RS-485 Modbus serial port, serial printing port, and USB host for pen drive connectivity, allowing for versatile data reporting options.
8. Reliable Alarm System: Features two independent user-settable set points for each channel with relay outputs, ensuring a reliable alarm system for critical conditions.
9. Error Condition Monitoring: Monitors temperature sensor errors, displaying ‘Break/Open’ or ‘Under/Over Range’ indications for RTD and all thermocouple inputs.
Technical Specifications:
1. Display: 4-digit LED display for process value and 2-digit LED display for channel number indication.
2. Control Action: Supports low/high control action for Alarm 1 and Alarm 2, user-programmable for specific applications.
3. LED Indication: Provides 8/16 RED LEDs for alarm and healthy indications, ensuring clear visual feedback for each channel.
4. Set Point: Two independent user-settable set points for each channel with 4 common relay outputs, offering precise control.
5. Relay Output: NO/C/NC relay contact rated 5A/230VAC for Alarm 1, Alarm 2, and additional relays. Remote acknowledgment facility for relays.
6. Monitoring of Error Conditions: Displays ‘Break/Open’ and ‘Under/Over Range’ indications for temperature sensor errors.
7. Scan Time: Field-programmable scan time between channels, ranging from 1 to 240 seconds.
8. Print Interval: Programmable print interval for direct printout on an optional 80-column dot matrix serial printer.
9. Logging Interval: Data logger model supports a logging interval of 1 to 9999 seconds, with a maximum memory capacity of 8000 readings for the 16-channel model.
Electrical Specifications:
1. Supply Voltage: Operates on 90 to 270 VAC, 50Hz, or 110 VDC to 270VDC.
Environmental Specifications:
1. Operating Temperature: -10°C to 60°C, ensuring functionality in a variety of environments.
2. Relative Humidity: Below 95% non-condensing, providing reliable performance in diverse humidity conditions.
Optional Features:
1. Isolated Communication Ports: Optional isolated RS-485-1 serial port with MODBUS RTU protocol output.
2. External Relay Module: Optional isolated RS-485-2 for an external alarm relay module.
3. Serial Printing Capability: Optional isolated serial port for direct printout on an 80-column dot matrix serial printer without the need for a computer.
4. USB Connectivity: Optional USB host (pen drive) connectivity for online and logged data reporting, supporting FAT-32 configured pen drives.
Panel Mount Housing:
1. Protection Class: IP-40, ensuring protection against dust and limited water ingress.
2. Cabinet Material: ABS plastic in black color, offering durability and a sleek appearance.
3. Cable Entry: Terminal connector for easy and secure connections.
4. Dimensions: 96mm (H) x 192mm (W) x 225mm (D) with connector, facilitating convenient panel mounting.
5. Weight: Approximately 1.5kg, providing a lightweight yet robust solution.
Pharmaceutical Warehouse Monitoring | ISO Certification Record Keeping and Validation Processes |
Online Profile Recording for Oven, BOD, Incubator, and Humidity Chamber | Pharmaceutical Warehouse Room Mapping |
Blood Bank Monitoring | Pharmaceutical Process Validation with Graphs and Excel Reports for Autoclaves |
Monitoring Winding Temperatures in Generators, Bearings, Motors, and Transformers | Heat Profile Monitoring in Furnaces and Foundries for Heat Treatment |
Primary and Auxiliary Temperature Scanning of Boilers | Monitoring in Chemical and Hazardous Areas Where Data Monitoring is Crucial |