Universal Data Logger | UIP-800D-PMH

The UIP-800-PM Universal Data Logger is a technologically advanced device designed for precise data acquisition and monitoring in various applications. With 8 universal input channels supporting a range of thermocouples, RTDs, and 4-20mA signals, this logger ensures versatility in temperature and process measurements. Featuring a user-friendly interface with a membrane keypad for on-field calibration, the device offers flexibility with programmable scan and logging intervals. The optional RS-485 Modbus Serial Port, USB Host (Pen Drive) connectivity, and external relay module enhance its functionality, providing options for data reporting, communication, and relay control. Ideal for applications such as ISO certification records, pharmaceutical process validation, and temperature profiling in furnaces or incubators, this data logger excels in diverse environments. It offers reliability with error monitoring, acknowledging remote relays, and dual set points with programmable relay outputs. The compact and sturdy panel mount housing, constructed from ABS plastic, ensures durability with an IP-40 protection class. Whether used in pharmaceuticals, manufacturing, or hazardous areas, the UIP-800-PM Universal Data Logger proves to be a reliable solution for efficient and accurate data monitoring.

1. Microcontroller Technology: Universal Data Logger Incorporates the latest microcontroller-based technology for enhanced accuracy in data acquisition.
2. Universal Input Channels: 8 channels Universal Data Logger supporting various thermocouples (J, K, R, S, T, B, N), RTDs (PT-100), and 4-20mA signals, offering versatile temperature and process monitoring.
3. Field Calibration: Allows easy on-field calibration through a front-panel membrane keypad, ensuring precise and reliable measurements.
4. Flexible Programming: User-programmable channel scan time (1 to 240 sec), logging interval (1 to 9999 sec), and printing interval (1 to 9999 sec) for tailored data collection.
5. Remote Acknowledgment: Facilitates remote acknowledgment for relays, providing convenient control over alarms and indicating the health status.
6. Optional Communication Ports: Offers optional RS-485 Modbus Serial Port for communication, optional serial printing port, and USB Host (Pen Drive) connectivity for online and logged data reports.
7. Relay Outputs: Provides separate relay outputs per channel for Alarm-1, Alarm-2, and Healthy Indication, enhancing control and notification capabilities.
8. Applications Across Industries: Versatile applications include ISO certification records, pharmaceutical process validation, temperature profiling in various environments (ovens, BOD incubators, humidity chambers), and more.

Technical Specifications:

1. Display: 4-digit LED display for Process Value and 2-digit LED display for Channel Number indication.
2. Control Action: Low/High control action for Alarm 1 & Alarm 2, user programmable.
3. Setting and Indication: Setting through front-panel keys, LED indication for Alarm 1, Alarm 2, and Healthy indications for each channel.
4. LED Indication: 8 Red LEDs (3mm) for visual indication of Alarm 1, Alarm 2, and Healthy status for channels.
5. Relay Output: 1 NO/C/NC Relay Contact (Rated 5A/230VAC) for each of the four relays, with remote acknowledgment capability.
6. Error Monitoring: Monitors temperature sensor conditions such as ‘Break/Open’ with specific display indications for Break, Under range, and Over range.
7. Scan and Logging Time: User-programmable scan time (1 to 240 sec) and logging interval (1 to 9999 sec) for precise data collection.
8. Memory Capacity: Supports up to 8000 readings storage capacity for the 8-channel Data Logger model.

Electrical and Environmental:

1. Supply Voltage: Supports a wide range of supply voltage – 90 to 270 VAC (50Hz) or 110 VDC to 270VDC.
2. Operating Conditions: Operates in temperatures ranging from -10°C to 60°C with below 95% non-condensing relative humidity.

Optional Features:

1. Communication Options: Isolated RS-485-1 serial port with MODBUS RTU protocol output for enhanced connectivity.
2. Alarm Relay Module: Isolated RS-485-2 for an external alarm relay module, providing additional control options.
3. Direct Printing: Isolated serial port for direct printout on an 80-column Dot Matrix serial printer without the need for a computer.
4. USB Connectivity: USB Host (Pen Drive) connectivity for immediate online and log data reporting.

Panel Mount Housing:

1. Protection Class: IP-40 for effective protection against dust and ingress.
2. Cabinet Material: Constructed with durable ABS plastic in black color.
3. Dimensions and Weight: Compact panel mount housing with dimensions of 96mm (H) x 192mm (W) x 225mm (D), weighing approximately 1 kg.

Fertilizer Plants Oil & Gas Industries
Chemical Storage Areas Refineries
Chemical Processing Plants Offshore Drilling & Processing Platforms
Gas Metering Stations Bullet Yards / Storage Yards
Gas Pipeline Projects Chemical & Petrochemical Plants
Hotel Industries Power Industrial Plants

Get Quote From Our Sales Team