Ambetronics' Toxic Gas Detector - Specifications, Certifications, Installation
GT-2511-FLP
Smart Gas Detector L.E.D Display
GT-2500-FLP
Smart Gas Detector LCD Display
GT-1033-FLP
2 Wire Loop Powered Transmitter
GT-4220-FLP
Gas Leak Detector for Combustible Gases
GLA-222-FLP
Gas Leak Alert
GLA-222-B
Gas Leak Detector for Domestic Kitchens for Detecting Leak of LPG & PNG Gas
Ambetronics Toxic Gas Detector – Your Shield Against the Unseen Threats!
Our Standard Certifications
Ambetronics Toxic Gas Detector has earned prestigious certifications attesting to its high standards of safety and performance. Certified by the Central Institute of Mining and Fuel Research (CIMFR) and the Petroleum and Explosives Safety Organization (PESO), the detector holds Ex db IIC T6 Gb IP 66 and Ex db IIC T6 Gb IP 68 flameproof enclosure certifications. Additionally, it complies with international standards such as IS/IEC 60079-1:2014 for Flameproof Protection, IS/IEC 60079-31:2013 for Dust Ignition Protection, IS/IEC 60079-11:2011 for Intrinsically Safe operation, and IS/IEC 60529:2001 for Ingress Protection. These certifications underscore the Ambetronics Toxic Gas Detector’s reliability and adherence to the highest safety protocols in hazardous environments.
What are the Various Steps to Detect Toxic Gas?
To ensure safety in industrial environments, detecting toxic gases is a multi-step process involving advanced technologies like Electrochemical, Catalytic, Pellistor, NDIR, PID, and Solid State. Ambetronics Toxic Gas Detector employs a diffusion-based detection method for quick and reliable output.
Why Choose Ambetronics Toxic Gas Detector Solution?
- Fast and reliable detection of Oxygen, Toxic, Combustible, and Volatile Organic Compounds (VOC).
- Smart pluggable gas sensor module for various gases.
- Calibration and alarm data stored in the sensor module for easy maintenance.
- Highly resistant to poisoning and etching.
- Capable of detecting down to PPM, %V/V, %LEL, mg/m3.
- Two-line, four-digit LED display and indicators for various statuses.
- Non-intrusive programming and password-protected settings.
- Multiple certifications for flameproof and intrinsic safety.
Ambetronics Toxic Gas Leak Detector – Your Shield Against the Unseen Threats!
List of Gases for Ambetronics Gas Detector
Sr. No. | Gases | Range | Unit | Resolution |
---|---|---|---|---|
T1 | Ammonia (NH) | 100 | PPM | 1 |
T2 | Ammonia (NH) | 1000 | PPM | 1 |
T3 | Bromine (Br.) | 20 | PPM | 0.1 |
T4 | Carbon Monoxide (CO) | 1000 | PPM | 1 |
T5 | Carbon Monoxide (CO) | 2000 | PPM | 1 |
T6 | Chlorine (CL) | 10 | PPM | 0.1 |
T7 | Ethylene Oxide (ETO) | 100 | PPM | 1 |
T8 | Hydrogen (H.) | 2000 | PPM | 1 |
T9 | Hydrogen Bromide (HBr) | 20 | PPM | 1 |
T10 | Hydrogen Chloride (HCL) | 20 | PPM | 1 |
T11 | Hydrogen Cyanide (HCN) | 100 | PPM | 1 |
T12 | Hydrogen Fluoride (HF) | 10 | PPM | 0.01 |
T13 | Hydrogen Fluoride (HF) | 100 | PPM | 1 |
T14 | Hydrogen Sulfide (H,S) | 100 | PPM | 1 |
T15 | Ozone (0) | 5 | PPM | 0.01 |
T16 | Phosphine (PH) | 10 | PPM | 0.1 |
T17 | Nitrogen Dioxide (NO) | 20 | PPM | 0.1 |
T18 | Nitric Oxide (NO) | 250 | PPM | 1 |
T19 | Sulfur Dioxide (SO) | 50 | PPM | 0.1 |
T20 | Sulfur Dioxide (SO) | 2000 | PPM | 1 |
Ambetronics Toxic Gas Detection System – Your Shield Against the Unseen Threats!
Installation Criteria of Toxic Gas Detector
Installation of the Ambetronics Toxic Gas Detector involves considering factors like gas density, ventilation, and potential gas leak sources. Ensure proper placement for optimal detection.
How to Calibrate Toxic Gas Detector?
Calibrating the detector involves using a magnetic wand without opening the enclosure cover. The process ensures accurate and reliable readings for various gases.
Why Choose Ambetronics Toxic Gas Detector Solution?
- Robust Technology: Utilizes advanced sensor technologies for accurate detection.
- Certification: Complies with industry standards for flameproof and intrinsic safety.
- Customizable Settings: Non-intrusive programming with password protection.
- Wide Range of Applications: Suitable for various industries and environments.
- Maintenance-Friendly: Calibration and alarm data stored in the sensor module for easy servicing.
Ambetronics Toxic Gas Detectors – Your Shield Against the Unseen Threats!
FAQs
Can the gas sensor modules be replaced?
Yes, Ambetronics Smart Gas Detector allows easy replacement of gas sensor modules for versatility.
How often should calibration be performed?
Calibration frequency depends on usage and environmental conditions but is generally recommended annually.
Is the detector affected by extreme temperatures?
Ambetronics Toxic Gas Detector is designed to operate within a specified temperature range, ensuring reliability.
Can I install the detector myself, or is professional assistance required?
Professional installation is recommended to ensure correct placement and optimal performance.
Does Ambetronics offer training on using the Toxic Gas Detector?
Yes, Ambetronics provides training sessions for proper usage, calibration, and maintenance of the detector.