Ambetronics

Smart Dual Channel Gas Detector – GT-5022-WP

The GT-5022-WP Smart Dual Channel Gas Detector offers advanced detection capabilities for a range of gases including Oxygen, Toxic, Combustible Gases, and Volatile Organic Compounds (VOC). Equipped with dual gas concentration indication, this detector ensures fast and reliable detection of even the smallest gas leaks. Its innovative design allows for easy maintenance and servicing, with calibration, alarm, and offset data stored directly in the sensor module. Featuring a digital display for clear gas concentration readouts and a host of alarm indicators, it provides versatile output options including standard 4-20mA signal and optional RS-485 communication. Ideal for a wide array of applications spanning from refineries and chemical plants to automotive industries and confined spaces, this weatherproof detector is a robust solution for gas monitoring needs in various industrial settings.

1. Dual Gas Concentration Indication: Smart Dual Channel Gas Detector simultaneously displays the concentration of two gases for comprehensive monitoring.
2. Multiple Gas Sensor Compatibility: Allows connection of two gas sensor modules, accommodating Oxygen, Toxic, Combustible, PID, and NDIR sensors.
3. Fast and Reliable Detection: Smart Dual Channel Gas Detector provides swift and accurate detection of Oxygen, Toxic, Combustible Gases, and VOCs, including the smallest leaks.
4. Smart Pluggable Sensor Modules: Enables easy maintenance and servicing by saving calibration, alarm, offset, and output current data within the sensor module.
5. Resistance to Poisoning and Etching: Highly resilient design ensures durability in harsh environments.
6. Wide Detection Range: Capable of detecting gas concentrations down to PPM, %V/V, and %LEL.
7. Digital Gas Concentration Display: Clear LCD display for easy readouts of gas concentrations.
8. Comprehensive Alarm Indication: Alerts for ‘Sensor Open’, ‘Over Range’, ‘Sensor Replace’, ‘Cal Due’, ‘Cal Fail’, and mA Loop Open conditions.
9. Configurable Signal Outputs: Offers standard 4-20mA signal output with configurable range, along with 0-10V, 0-5V, and 0-1V voltage output options.
10. Optional STEL and TWA Set Points: Configurable set points for Toxic and VOC gases provide flexibility in monitoring.
11. Optional RS-485 Communication: Enables communication via MODBUS RTU protocol for integration with control systems.
12. Non-Intrusive Programming: Flameproof model allows programming adjustments using front keys without compromising safety.
13. Password Protection: Secures programming with password protection and allows for password changes.
14. Alarm Acknowledgement: Facility for acknowledging alarms from both front and rear terminals.
15. Test Mode: Allows testing of electronics, alarm LEDs, relays, and output current/voltage with or without a sensor module.
16. Optional Alarm Relay Contacts: On-board relay contacts with configurable alarm levels and fail-safe relay for added safety.

Technical Specifications:

1. Sensor Technology: Electrochemical, Catalytic, Pellistor, NDIR, or PID depending on the gas being detected.
2. Detection Method: Diffusion for effective gas detection.
3. Gas Detected: Oxygen, Toxic, Combustible Gases, and VOCs.
4. Range and Resolution: Configurable ranges and resolutions as specified.
5. Display: Graphic LCD with adjustable backlight and 8 LEDs for status indication.
6. Control Action: Dual independent alarm set points with latch and non-latch options, user-selectable hysteresis, and logic.
7. Response Time: Less than 15 seconds for rapid detection.
8. Supply Voltage: 18 to 36 VDC, typically 24VDC.
9. Power Consumption: Less than 3.6 Watts for efficient operation.
10. Output Signal: Standard 4-20mA current output with configurable range, and optional 0-10V, 0-5V, or 0-1V voltage outputs.
11. Error Monitoring: Comprehensive monitoring for sensor break/open, over-range, output current/voltage open conditions, with configurable settings.
12. Environmental Conditions: Operating temperature range of -15 to +50°C, storage temperature range of -10 to 60°C, humidity less than 95% non-condensing.
13. Weatherproof Housing: Constructed from ABS plastic with PG 12 cable gland for cable entry, suitable for wall mounting, dimensions 182mm (H) x 214mm (W) x 81.5mm (D), weighing approximately 950g.
14. Accessories: Optional accessories include certified power supply, canopy, mounting stand, gas calibration kit, hooter cum flasher, gas sampling & conditioning system, communication converters, and SCADA software.
15. Common Deliverables: Test calibration certificate, reference calibration gas certificate, operational/instrument user manual, and standard mounting hardware.

Refineries Cold Storage
Sewage Plants Fertilizers Plants
Stack Monitoring Chlorination Plant
Gas Cylinder Bank Ambient Monitoring
Gas Metering skid Gas Metering Station
Pulp & Paper Plants Bullets Yards/ storage yards
Chemical Processing Plant Heat Treatment Plants
Chemical Storage Area Power & Industrial Plants
Acid Alkalizes & Dyes Mfg. Plants Coal Mine and Confined Area
Chemical & Petrochemical Plants Gas Pipeline Project
Oil & Gas Industries Burner / Furnace Areas
Control Atmosphere Automotive Industries / Paint Shops

Get Quote From Our Sales Team